A, external failure phenomenon elimination method
1. No electricity, black screen:
(1) when the machine appear the phenomenon first check the power plug, socket, wiring for loose, switch (OSD button or remote control) is open;
(2) if the machine is equipped with a timer timer will be expected to see the red light and green light is lit at the same time, if only the red indicator light and green light is not on, the clock Settings might be the problem, only the clock set up correctly, (see instructions) failures can be ruled out;
(3) the timing function, such as machine software is to check the software clock is set correctly (see instructions).
2. Have images without sound
Check to see if the sound is set to minimum or silent mode, resetting the volume model. (see instructions)
Such as offline, no sound, first check to see if external voice line is damaged, the connection is correct.
3. Don't read CF card
CF card in the documentation is not correct, re-established LOOP document; Encryption machine needs to be encrypted advertising (see instructions)
4. If the above method can't eliminate your problems, refer to see two internal fault phenomenon elimination method.
2. Internal failure phenomenon elimination method:
1. No electricity (black screen) : it could be the built-in power bad or bad driving plate machine; Screening methods: check the power supply output is normal, such as poor power supply have no output is to confirm the power, if the output power is normal, it is likely to be driven plate undesirable.
2. Flower screen: within an area and has been on the surface of the LCD screen does not display or display abnormal called flowers screen; Screening methods: see if inserted on the LCD screen of signal transmission lines, the phenomenon such as separation caused by poor contact, such as this case insert signal lines and is fixed, and view the problem is solved; If there is no bad the situation may be the LCD panel.
3. The dark screen (screen no display, the splash screen) : advertising has been in the black screen LCD screen, dark screen, the situation such as the splash screen is called the dark screen. Method: check the power supply output is normal, such as power supply output voltage instability (voltage value not reached 11 ~ 12 v) can confirm the power, if the output power is normal, it need to be replaced by the driven plate and the inverter, until the troubleshooting.
4. Don't read the card, such as the external cause of the problem doesn't exist, need to change the decoding board (board).
5. No signal: electric screen appears when no signal, called no signal. Elimination method: check the internal video line and the input to the 5 v power supply cord decoder board is loose, if there is no this phenomenon need to replace decoding board or driver board, after the change and see whether the fault disappear.
6. After electrify screen automatic cycle of red, green, and blue images, such as elimination method: loose signal lines or driver board.